KANE-LCA Landlord Gas Safety Analyser
Applications
- CP12 Landlord Gas Safety Certificates
- TB143 Boiler Commissioning test
- BS7967 2 minute Appliance Sweep Test
Measures
- Single input pressure to 1psi, -80 to +80mBar
- CO to 2000pm with 4000 pm over range protection
- CO2 & O2 to 20.9%
- Temperature -20 to +1350ºC
Box Contents
KANE-LCA
- Supplied with CP2 & CP35 combustion probes, SM50056 high capacity water trap & particle filter, 3 x AA batteries, USB charger, MSC00237 protective case & wireless
SM50056
- High capacity water trap & particle filter
CP35
- 300mm flexible probe
- 8mm diameter
- 2m neoprene hose
KANE LIVE
- Fitted as standard
- See, save & share tests
Independently tested by TUV SUD to EN50379
Use for BS7967 & TB143
Request a quotation
Configure the product below and submit it to your quote basket.
Pricing will be supplied privately with your quotation.
Contact us
Applications
- CP12 Landlord Gas Safety Certificates
- TB143 Boiler Commissioning test
- BS7967 2 minute Appliance Sweep Test
Measures
- Single input pressure to 1psi, -80 to +80mBar
- CO to 2000pm with 4000 pm over range protection
- CO2 & O2 to 20.9%
- Temperature -20 to +1350ºC
Box Contents
KANE-LCA
- Supplied with CP2 & CP35 combustion probes, SM50056 high capacity water trap & particle filter, 3 x AA batteries, USB charger, MSC00237 protective case & wireless
SM50056
- High capacity water trap & particle filter
CP35
- 300mm flexible probe
- 8mm diameter
- 2m neoprene hose
KANE LIVE
- Fitted as standard
- See, save & share tests
Independently tested by TUV SUD to EN50379
Use for BS7967 & TB143
No downloads available for this product.